Industry
Exhibitions
Companys

GW4 Series Double Column Center Break Design with Self Cleaning Contacts

05 18, 2026
Posted By: Peter

The GW4 Series Outdoor High Voltage Disconnector features a proven double-column center-break design that has become an industry standard for 40.5kV to 126kV outdoor isolation applications. This mechanical configuration, where two insulator columns rotate horizontally to open the circuit at the center, offers exceptional visibility of the open gap and reliable performance across a wide range of environmental conditions . The center-break geometry inherently provides a large, visible isolating distance that exceeds standard clearance requirements .

A key innovation in the GW4 series is the self-cleaning contact system. Unlike traditional designs where fixed contact springs are vulnerable to corrosion and thermal degradation, the GW4 employs contact fingers manufactured from new high-strength, high-conductivity, and high-elasticity materials . These fingers generate their own clamping force without relying on external springs, eliminating failure modes associated with spring corrosion (weakened grip) or thermal annealing (increased resistance and overheating).

The double-column configuration also enhances operational safety. When the switch is open, the visible break distance is immediately apparent to operators performing lockout/tagout procedures. The center-break design requires minimal rotational force—just 90° of movement—achieved through precision bearings and sealed rotating bases . The mechanical life is rated for 2000 operations, verified through rigorous type testing per GB1985 and IEC62271-102 standards .

For maintenance accessibility, the center-break design allows each phase to be inspected and serviced independently. The contact surfaces are arranged such that the self-cleaning wiping action during opening and closing removes oxidation and contamination, preserving low contact resistance without specialized cleaning . The contact fingers can be individually replaced if worn, extending overall service life significantly beyond the rated mechanical endurance .

Therefore, for utilities and industrial facilities requiring reliable, visible isolation with minimal maintenance, the GW4's double-column center-break design with self-cleaning contacts delivers field-proven performance. Putai also supports customization and the supply of related medium-voltage accessories to meet system integration needs. For detailed dimensional drawings and technical specifications for your voltage rating, contact our engineering team.
(Article content references network resources.)

Main News
24 Jun, 2026
Why Pole Mounted Reclosers Are Essential in Modern Distribution Networks
As power distribution networks become more complex and customer expectations for uninterrupted electricity continue to rise, utilities face increasing pressure to improve reliability, reduce outage du
View More
22 Jun, 2026
ZW32 15 6kV Integrated Sensors Enable Precision Grid Monitoring and Protection
The ZW32-15.6kV Outdoor Pole Mounted Vacuum Auto Recloser incorporates advanced integrated sensor technology that provides the critical data needed for modern distribution automation. Equipped with th
View More
11 Jun, 2026
ZN63 VS1 12 Drawer Breaker Installation Commissioning and Maintenance Guide
Proper installation, commissioning, and maintenance of the ZN63(VS1)-12 Drawer-Type Vacuum Circuit Breaker are essential for ensuring long-term reliability and safety. Following established procedures
View More
Experts Provide Services For You!
More Related Products
LZZBJ15-12 12kV Current Transformer
  • Dual Windings:Supports both measuring and protection circuits.
  • Epoxy Insulated:Fully enclosed resin structure enhances durability.
  • High Insulation:Rated insulation level up to 12/28/75kV.
  • Standards Compliant:Meets IEC 60044-1 and IEC 61869-1/2.
  • Indoor Use:Designed for enclosed, medium-voltage switchgear.
  • Stable Operation:Provides long-term performance under normal conditions.
JDZ-12Q, JDZJ-12Q Semi-enclosed Voltage Transformer
  • Double-Pole Insulation:Enhanced electrical safety with epoxy resin casting.
  • High Reliability:Stable performance for voltage measurement and protection.
  • Low Core Magnetism:Reduces measurement errors.
  • Maintenance Free:Designed for long-term operation without regular servicing.
  • Wide Application:Suitable for single-phase and three-phase AC circuits.
  • Standards Compliance:Meets IEC 60044-2 & IEC 61869-1/3 standards.
LDZC-10 Phase-Sequence Through-Core Current Transformer
  • Through-Core Design:Primary bushing or cable passes through the core
  • Fully Enclosed:Secondary windings housed in flame-retardant plastic
  • Easy Installation:Bottom installation inserts for secure mounting
  • Secondary Current:Available in 5A and 1A
  • Voltage Withstand:Power frequency withstand voltage of 3kV
  • Standards Compliant:Meets IEC 60044-1 and IEC 61869-1 & 2
  • Indoor Use:Suitable for indoor medium voltage applications
JSZY18-24RJ Voltage Transformer
  • Epoxy Cast Body:Full encapsulation ensures insulation and durability
  • Elbow Plug Design:Enhances moisture protection and installation ease
  • Pollution Resistance:Performs well in dusty or humid environments
  • Voltage Rating:Compatible with systems up to 24kV
  • Standard Frequency:Designed for 50Hz or 60Hz operation
  • Indoor Application:Ideal for isolated neutral power systems