The reliability of any SF6 insulated switchgear hinges on the integrity of its gas system. The PGS-12/24/40.5/630-20 features a state-of-the-art 304L stainless steel welded tank that achieves an ultra-low leakage rate of 1.1×10⁻⁷ cc/sec . This corresponds to less than a 1% pressure drop per year, ensuring maintenance-free operation for up to 30 years and significantly reducing the total cost of ownership compared to conventional designs.

The switch utilizes a comprehensive pressure management strategy with defined thresholds. At 20°C, the nominal gas pressure is set between 0.05 and 0.07 MPa (gauge) . A visible factory-calibrated gauge allows for quick visual inspection without specialized tools. To protect against extreme overpressure scenarios (e.g., internal arcing), the tank is fitted with a bursting disc that activates at 0.6 MPa (6 kgf/cm²), safely venting gases away from the operator via a designated exhaust channel, complying with internal arc classification (IAC) .

Furthermore, the PGS incorporates a low-pressure interlock. When the gas pressure drops below 0.05 MPa—which could compromise dielectric strength—the mechanism automatically locks out the closing operation . This prevents damage from operating the switch under insufficient insulation. The system also provides a visual alarm flag, giving operators a clear, unmistakable indication that the switch is out of service due to low gas.

The triangular spring energy storage mechanism is hermetically sealed within this gas-tight chamber, protecting it from corrosion and dust. This combined approach of robust tank design, precise pressure monitoring, and proactive safety interlocks makes the PGS one of the most reliable pole-mounted switches available for critical infrastructure.

Therefore, for utilities prioritizing long-term reliability and personnel safety, the PGS series offers best-in-class SF6 management and failsafe operation. Putai also supports customization and the supply of related medium-voltage accessories to meet system integration needs.
(Article content references network resources.)

Main News
24 Jun, 2026
Why Pole Mounted Reclosers Are Essential in Modern Distribution Networks
As power distribution networks become more complex and customer expectations for uninterrupted electricity continue to rise, utilities face increasing pressure to improve reliability, reduce outage du
View More
22 Jun, 2026
ZW32 15 6kV Integrated Sensors Enable Precision Grid Monitoring and Protection
The ZW32-15.6kV Outdoor Pole Mounted Vacuum Auto Recloser incorporates advanced integrated sensor technology that provides the critical data needed for modern distribution automation. Equipped with th
View More
11 Jun, 2026
ZN63 VS1 12 Drawer Breaker Installation Commissioning and Maintenance Guide
Proper installation, commissioning, and maintenance of the ZN63(VS1)-12 Drawer-Type Vacuum Circuit Breaker are essential for ensuring long-term reliability and safety. Following established procedures
View More
Experts Provide Services For You!
More Related Products
LZZBJ15-12 12kV Current Transformer
  • Dual Windings:Supports both measuring and protection circuits.
  • Epoxy Insulated:Fully enclosed resin structure enhances durability.
  • High Insulation:Rated insulation level up to 12/28/75kV.
  • Standards Compliant:Meets IEC 60044-1 and IEC 61869-1/2.
  • Indoor Use:Designed for enclosed, medium-voltage switchgear.
  • Stable Operation:Provides long-term performance under normal conditions.
JDZ-12Q, JDZJ-12Q Semi-enclosed Voltage Transformer
  • Double-Pole Insulation:Enhanced electrical safety with epoxy resin casting.
  • High Reliability:Stable performance for voltage measurement and protection.
  • Low Core Magnetism:Reduces measurement errors.
  • Maintenance Free:Designed for long-term operation without regular servicing.
  • Wide Application:Suitable for single-phase and three-phase AC circuits.
  • Standards Compliance:Meets IEC 60044-2 & IEC 61869-1/3 standards.
LDZC-10 Phase-Sequence Through-Core Current Transformer
  • Through-Core Design:Primary bushing or cable passes through the core
  • Fully Enclosed:Secondary windings housed in flame-retardant plastic
  • Easy Installation:Bottom installation inserts for secure mounting
  • Secondary Current:Available in 5A and 1A
  • Voltage Withstand:Power frequency withstand voltage of 3kV
  • Standards Compliant:Meets IEC 60044-1 and IEC 61869-1 & 2
  • Indoor Use:Suitable for indoor medium voltage applications
JSZY18-24RJ Voltage Transformer
  • Epoxy Cast Body:Full encapsulation ensures insulation and durability
  • Elbow Plug Design:Enhances moisture protection and installation ease
  • Pollution Resistance:Performs well in dusty or humid environments
  • Voltage Rating:Compatible with systems up to 24kV
  • Standard Frequency:Designed for 50Hz or 60Hz operation
  • Indoor Application:Ideal for isolated neutral power systems
Inquiry Basket()
GET IN TOUCH NOW
Captcha Code
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All